/Uploads/1922019104.jpg

Alev İlerletmeyen

Bu ürün grubu jelkotlar alev ilerletmeme özelliğine sahip olup özellikle elektrik panoları, kara, hava ve deniz taşıtlarının motor ve eksoz bölümlerinin, elektronik devrelerinin bulunduğu özel bölümlerinin üretimi için özel olarak tasarlanmıştır. Dolgulu ve özel dolgulu olan bu jelkotlar fırça ile uygulamaya uygun olup talep edildiği takdirde renkli olarak üretilebilmektedir.

GFR-40/R Specific resin based, halogen free brush type fire retardant filled gelcoat
PROPERTIES FIELD OF APPLICATION TECHNICAL PROPERTIES
Contains specific fillers Railroad vehicles, metro and train wagons Chemical base Specific
Halogen free Car, bus and truck body parts Application Brush
Roller
DIN 5510-2 certified (S4, SR2, ST2) Electrical circuit boards and pannels Viscosity (cps) 10000 – 14000 
Does not produce toxic gas during fire and cooling stage    Thixotropy Yes
Resistant to UV light   Density(gr/cm3) 20°C 1,55 – 1,60   
Should be used with fire retardant paints for exterior usage   Monomer content (%) 18 – 20 
    Gel time (min) 25 – 35 (*)
    Exothermic peak (°C) 75 – 85 (*)
    Curing system (*) 1% MEK P, pre-accelerated
       

Comments
Composite laminate with FR-40 (DIN 5510-2) was certified according to DIN 5510-2 by accredited RST laboratory first in 2014

GFR-4/R Specific resin based, halogen free spray-up fire retardant filled gelcoat
PROPERTIES FIELD OF APPLICATION TECHNICAL PROPERTIES MECHANICAL PROPERTIES(**)
Contains specific fillers Railroad vehicles, metro and train wagons Chemical base Specific Tensile strength (MPa) 70– 80
Halogen free Car, bus and truck body parts Application Spray-up Tensile elongation (%) 2,5 – 3,5
DIN 5510-2 certified (S4, SR2, ST2) Electrical circuit boards and pannels Viscosity (cps) 3000 – 4000  Tensile E-modulus (MPa) 3000 – 4000 
Does not produce toxic gas during fire and cooling stage    Thixotropy Yes Flexural strength (MPa) 150 – 160      
Resistant to UV light   Density(gr/cm3) 20°C 1,07 – 1,09   Hardness (barcol) 30 - 32
Should be used with fire retardant paints for exterior usage   Monomer content (%) 30 – 34    Heat distortion temperature (°C) 95 – 98
    Gel time (min) 25 – 35 (*) Water absorption (mg) 34 – 36 
    Exothermic peak (°C) 75 – 85 (*)    
    Curing system (*) 1% MEK P, pre-accelerated  
        (**) Test applied as polyester after post cure application

Comments
Composite laminate with FR-40 (DIN 5510-2) was certified according to DIN 5510-2 by accredited RST laboratory first in 2014

GFR-345/R Specific resin based, halogen free brush type fire retardant filled gelcoat
PROPERTIES FIELD OF APPLICATION TECHNICAL PROPERTIES
High performance fire retardant characteristic  Railroad vehicles, metro and train wagons Chemical base Specific
Contains specific fillers Car, bus and truck body parts Application Brush
Roller
Halogen free Electrical circuit boards and pannels Viscosity (cps) 15000 – 20000 
EN 45545-2 certified (HL 2)    Thixotropy Yes
Does not produce toxic gas during fire and cooling stage    Density(gr/cm3) 20°C 1,50 – 1,60   
Resistant to UV light   Monomer content (%) 23 - 26
Should be used with fire retardant paints for exterior usage   Gel time (min) 15 – 25 (*)
    Exothermic peak (°C) 75 – 85 (*)
    Curing system (*) 1,3% Accelerator B + 2% MEK P
       

Comments
Composite laminate with FR-40 (EN 45545-2) was certified according to EN 45545-2 by accredited RST laboratory in 2015

GFR-445/R Specific resin based halogen free brush type fire retardant filled gelcoat
PROPERTIES FIELD OF APPLICATION TECHNICAL PROPERTIES
High performance fire retardant characteristic  Railroad vehicles, metro and train wagons Chemical base Specific
Contains specific fillers Car, bus and truck body parts Application Spray-up
Halogen free Electrical circuit boards and pannels Viscosity (cps) 5000 – 6000 
EN 45545-2 certified (HL 2)    Thixotropy Yes
Does not produce toxic gas during fire and cooling stage    Density(gr/cm3) 20°C 1,40 – 1,50   
Resistant to UV light   Monomer content (%) 26 - 29
Should be used with fire retardant paints for exterior usage   Gel time (min) 15 – 25 (*)
    Exothermic peak (°C) 75 – 85 (*)
    Curing system (*) 1,3% Accelerator B + 2% MEK P
       

Comments
Composite laminate with FR-40 (EN 45545-2) was certified according to EN 45545-2 by accredited RST laboratory in 2015