Bu ürün grubu jelkotlar alev ilerletmeme özelliğine sahip olup özellikle elektrik panoları, kara, hava ve deniz taşıtlarının motor ve eksoz bölümlerinin, elektronik devrelerinin bulunduğu özel bölümlerinin üretimi için özel olarak tasarlanmıştır. Dolgulu ve özel dolgulu olan bu jelkotlar fırça ile uygulamaya uygun olup talep edildiği takdirde renkli olarak üretilebilmektedir.
| GFR-40/R | Specific resin based, halogen free brush type fire retardant filled gelcoat |
| PROPERTIES | FIELD OF APPLICATION | TECHNICAL PROPERTIES | |
|---|---|---|---|
| Contains specific fillers | Railroad vehicles, metro and train wagons | Chemical base | Specific |
| Halogen free | Car, bus and truck body parts | Application | Brush Roller |
| DIN 5510-2 certified (S4, SR2, ST2) | Electrical circuit boards and pannels | Viscosity (cps) | 10000 – 14000 |
| Does not produce toxic gas during fire and cooling stage | Thixotropy | Yes | |
| Resistant to UV light | Density(gr/cm3) 20°C | 1,55 – 1,60 | |
| Should be used with fire retardant paints for exterior usage | Monomer content (%) | 18 – 20 | |
| Gel time (min) | 25 – 35 (*) | ||
| Exothermic peak (°C) | 75 – 85 (*) | ||
| Curing system (*) | 1% MEK P, pre-accelerated | ||
Comments
Composite laminate with FR-40 (DIN 5510-2) was certified according to DIN 5510-2 by accredited RST laboratory first in 2014
| GFR-4/R | Specific resin based, halogen free spray-up fire retardant filled gelcoat |
| PROPERTIES | FIELD OF APPLICATION | TECHNICAL PROPERTIES | MECHANICAL PROPERTIES(**) | ||
|---|---|---|---|---|---|
| Contains specific fillers | Railroad vehicles, metro and train wagons | Chemical base | Specific | Tensile strength (MPa) | 70– 80 |
| Halogen free | Car, bus and truck body parts | Application | Spray-up | Tensile elongation (%) | 2,5 – 3,5 |
| DIN 5510-2 certified (S4, SR2, ST2) | Electrical circuit boards and pannels | Viscosity (cps) | 3000 – 4000 | Tensile E-modulus (MPa) | 3000 – 4000 |
| Does not produce toxic gas during fire and cooling stage | Thixotropy | Yes | Flexural strength (MPa) | 150 – 160 | |
| Resistant to UV light | Density(gr/cm3) 20°C | 1,07 – 1,09 | Hardness (barcol) | 30 - 32 | |
| Should be used with fire retardant paints for exterior usage | Monomer content (%) | 30 – 34 | Heat distortion temperature (°C) | 95 – 98 | |
| Gel time (min) | 25 – 35 (*) | Water absorption (mg) | 34 – 36 | ||
| Exothermic peak (°C) | 75 – 85 (*) | ||||
| Curing system (*) | 1% MEK P, pre-accelerated | ||||
| (**) Test applied as polyester after post cure application | |||||
Comments
Composite laminate with FR-40 (DIN 5510-2) was certified according to DIN 5510-2 by accredited RST laboratory first in 2014
| GFR-345/R | Specific resin based, halogen free brush type fire retardant filled gelcoat |
| PROPERTIES | FIELD OF APPLICATION | TECHNICAL PROPERTIES | |
|---|---|---|---|
| High performance fire retardant characteristic | Railroad vehicles, metro and train wagons | Chemical base | Specific |
| Contains specific fillers | Car, bus and truck body parts | Application | Brush Roller |
| Halogen free | Electrical circuit boards and pannels | Viscosity (cps) | 15000 – 20000 |
| EN 45545-2 certified (HL 2) | Thixotropy | Yes | |
| Does not produce toxic gas during fire and cooling stage | Density(gr/cm3) 20°C | 1,50 – 1,60 | |
| Resistant to UV light | Monomer content (%) | 23 - 26 | |
| Should be used with fire retardant paints for exterior usage | Gel time (min) | 15 – 25 (*) | |
| Exothermic peak (°C) | 75 – 85 (*) | ||
| Curing system (*) | 1,3% Accelerator B + 2% MEK P | ||
Comments
Composite laminate with FR-40 (EN 45545-2) was certified according to EN 45545-2 by accredited RST laboratory in 2015
| GFR-445/R | Specific resin based halogen free brush type fire retardant filled gelcoat |
| PROPERTIES | FIELD OF APPLICATION | TECHNICAL PROPERTIES | |
|---|---|---|---|
| High performance fire retardant characteristic | Railroad vehicles, metro and train wagons | Chemical base | Specific |
| Contains specific fillers | Car, bus and truck body parts | Application | Spray-up |
| Halogen free | Electrical circuit boards and pannels | Viscosity (cps) | 5000 – 6000 |
| EN 45545-2 certified (HL 2) | Thixotropy | Yes | |
| Does not produce toxic gas during fire and cooling stage | Density(gr/cm3) 20°C | 1,40 – 1,50 | |
| Resistant to UV light | Monomer content (%) | 26 - 29 | |
| Should be used with fire retardant paints for exterior usage | Gel time (min) | 15 – 25 (*) | |
| Exothermic peak (°C) | 75 – 85 (*) | ||
| Curing system (*) | 1,3% Accelerator B + 2% MEK P | ||
Comments